AFL/Fujikura FSM-60S Fusion Splicer Full Kit- In stock
- Product Details
Features:
1. Rugged construction providing shock, dust and moisture resistance
2. Dual monitor position with automatic image orientation
3. Automatic arc calibration and fi ber identifi cation
4. User-selectable fi ber clamping method - sheath clamp or fi ber holders
5. Auto-start tube heater feature
6. Color LCD display with anti-refl ective coating for excellent visibility in bright sunlight
7. Simultaneous battery charge and splicer operation Fonsun Technology
8. Long life battery (up to 160 splice/heat cycles per charge)
9. Detachable work table incorporated into the transit case
10. Data and video download software included; software upgrade available via the internet
11. Green friendly-RoHS & WEEE compliant
Specifications:Applicable FibersSM(ITU-T G.652), MM (ITU-T G.651), DS (ITU -T G.653), NZDS (ITU-T G.655) and other single mode fiber including ITU-T G.657 fiberFiber countSingleApplicable fiber dimensionsCladding Diameter: 80μm to150μm
Coating Diameter:100μm to 1,000μmFiber setting and cleaved lengthSheathe clamp A (standard) : For coating dia. up to 250um (8 to 16mm cleave),
coating dia. Of over 250um (16um cleaver)
Sheathe clamp B (option) :For coating dia. up to 1000um (8 to 16mm cleave)
Sheathe clamp C (option) :For 900um dia. Loose tube fiber (8 to 16mm cleave)
Fiber holder (option) :FH-60-250 and FH-60-900 (10mm cleaver)Splicing Modes100 preset and user programmable modesTypical Average Splice Loss0.02dB with SM, 0.01dB with MM, 0.04dB with DS, 0.04dB with NZDS
(Measured by cut-back method relevant to ITU-T and IEC standards)Return loss60dBSplicing TimeTypical 9 sec. with SM FAST, 10sec. with SM AUTO and 13sec with AUTO modes with standard SM (ITU-T G.652)Splice Loss EstimateAvailableAttenuation splicer functionIntentional high splice loss of 0.1dB to 15dB (0.1dB step) can be made for an in-line fixed attenuatorTube heater / Heating TimeBuilt-in tube heater with 30 heating modes.Typical 30 seconds with FP-03 sleeve,Applicable Protection Sleeve60mm, 40mm and Fujikura FPS01 series.Storage of Splice ResultThe last 2000 results to be stored in the internal memoryTension Test1.96 to 2.25NOperating Condition0 to 5,000m above sea level, 0 to 95%RH and -10 to 50 degC and up to 15m/s wind velocity, respectivelyStorage Condition0 to 95%RH and -40 to 80 degC respectively.
Battery:-20 to 30 degC for long termDimensions136W x 161D x 143H (mm) / 5.3W x 6.3D x 5.6H (inches)Weight2.3 kg (5.1 lbs) with AC adapter ADC-13; 2.7kg with BTR-08Viewing MethodTwo CMOS cameras and 4.1 inch TFT color LCD monitorFiber view and
Magnification300X for single X or Y view, or 187X for X and Y viewPower SupplyApplicable voltage from 100 to 240V AC or 10 to 15V DC with ADC-13, 13.2V DC with BTR-08 batteryNo.of Splice Cycles with batteryTypical 160 cycles (splice / tube heat) with BTR-08Electrode life2500 arc-dischargesTerminalsUSB 1.1 (Mini-B type) connector for PC communication.
6-pin Mini-DIN connector for HJS-02/03 or SH-8 power supply
Fujikura FSM-60S Fusion Splicer Standard package:
a) Main body Model:FSM-60S - 1 pc;
b) Detachable AC Adapter & Battery charger Model: ADC-13 - 1 pc;
c) AC power cord Model: ACC-XX - 1 pc;
d) Spare electrode Model: ELCT2-20A -1pair;
e) Carrying case Model: CC-24-60S - 1pc;
f) Instruction manual (English version) - 1pc;
g) Video Instruction Manual, V-60S-E - 1pc;
h) High precision fiber cleaver Model:CT-30A- 1 pc;
i) Battery Pack Model: BTR-08 - 1pc;
j) Battery charge cord Model: DCC-14 -1 pc
k) Monitor cover Model: MC-02 1pc;
l)Cooling Tray Model:JP-05 - 1pc;
m) Sheath Clamp Model:CLAMP-S60A - 1pc.
One year warranty from us!
1. Rugged construction providing shock, dust and moisture resistance
2. Dual monitor position with automatic image orientation
3. Automatic arc calibration and fi ber identifi cation
4. User-selectable fi ber clamping method - sheath clamp or fi ber holders
5. Auto-start tube heater feature
6. Color LCD display with anti-refl ective coating for excellent visibility in bright sunlight
7. Simultaneous battery charge and splicer operation Fonsun Technology
8. Long life battery (up to 160 splice/heat cycles per charge)
9. Detachable work table incorporated into the transit case
10. Data and video download software included; software upgrade available via the internet
11. Green friendly-RoHS & WEEE compliant
Specifications:Applicable FibersSM(ITU-T G.652), MM (ITU-T G.651), DS (ITU -T G.653), NZDS (ITU-T G.655) and other single mode fiber including ITU-T G.657 fiberFiber countSingleApplicable fiber dimensionsCladding Diameter: 80μm to150μm
Coating Diameter:100μm to 1,000μmFiber setting and cleaved lengthSheathe clamp A (standard) : For coating dia. up to 250um (8 to 16mm cleave),
coating dia. Of over 250um (16um cleaver)
Sheathe clamp B (option) :For coating dia. up to 1000um (8 to 16mm cleave)
Sheathe clamp C (option) :For 900um dia. Loose tube fiber (8 to 16mm cleave)
Fiber holder (option) :FH-60-250 and FH-60-900 (10mm cleaver)Splicing Modes100 preset and user programmable modesTypical Average Splice Loss0.02dB with SM, 0.01dB with MM, 0.04dB with DS, 0.04dB with NZDS
(Measured by cut-back method relevant to ITU-T and IEC standards)Return loss60dBSplicing TimeTypical 9 sec. with SM FAST, 10sec. with SM AUTO and 13sec with AUTO modes with standard SM (ITU-T G.652)Splice Loss EstimateAvailableAttenuation splicer functionIntentional high splice loss of 0.1dB to 15dB (0.1dB step) can be made for an in-line fixed attenuatorTube heater / Heating TimeBuilt-in tube heater with 30 heating modes.Typical 30 seconds with FP-03 sleeve,Applicable Protection Sleeve60mm, 40mm and Fujikura FPS01 series.Storage of Splice ResultThe last 2000 results to be stored in the internal memoryTension Test1.96 to 2.25NOperating Condition0 to 5,000m above sea level, 0 to 95%RH and -10 to 50 degC and up to 15m/s wind velocity, respectivelyStorage Condition0 to 95%RH and -40 to 80 degC respectively.
Battery:-20 to 30 degC for long termDimensions136W x 161D x 143H (mm) / 5.3W x 6.3D x 5.6H (inches)Weight2.3 kg (5.1 lbs) with AC adapter ADC-13; 2.7kg with BTR-08Viewing MethodTwo CMOS cameras and 4.1 inch TFT color LCD monitorFiber view and
Magnification300X for single X or Y view, or 187X for X and Y viewPower SupplyApplicable voltage from 100 to 240V AC or 10 to 15V DC with ADC-13, 13.2V DC with BTR-08 batteryNo.of Splice Cycles with batteryTypical 160 cycles (splice / tube heat) with BTR-08Electrode life2500 arc-dischargesTerminalsUSB 1.1 (Mini-B type) connector for PC communication.
6-pin Mini-DIN connector for HJS-02/03 or SH-8 power supply
Fujikura FSM-60S Fusion Splicer Standard package:
a) Main body Model:FSM-60S - 1 pc;
b) Detachable AC Adapter & Battery charger Model: ADC-13 - 1 pc;
c) AC power cord Model: ACC-XX - 1 pc;
d) Spare electrode Model: ELCT2-20A -1pair;
e) Carrying case Model: CC-24-60S - 1pc;
f) Instruction manual (English version) - 1pc;
g) Video Instruction Manual, V-60S-E - 1pc;
h) High precision fiber cleaver Model:CT-30A- 1 pc;
i) Battery Pack Model: BTR-08 - 1pc;
j) Battery charge cord Model: DCC-14 -1 pc
k) Monitor cover Model: MC-02 1pc;
l)Cooling Tray Model:JP-05 - 1pc;
m) Sheath Clamp Model:CLAMP-S60A - 1pc.
One year warranty from us!
Product Searches
fiber optic fusion splicer,stock w910i,stock phone,full wat,telephone stock,fiber cable splicer,optical fiber splicer,fusion protective sleeve,fusion splicers system,optical fiber fusion,sim kit,charger kit,stock watch mobile,stock nokia n73,full boxed phones,full color cards,stock nokia n82,blackberry 9000 full housing,full tv box,stock phone manufacturers,spare parts stock,v3 full housing